Quick Links
- Network Map
- List of Stations
- Monthly Report Card
- Quarterly Report Card
- Network Status Page
- Potsdam CPF time bias service
- Procedure for estimating laser beam divergence
- Recent Station Upgrades
- Network station application form
- Revised ILRS station screening process at ILRS Operations Centers (NASA and EDC)
Tateyama: Site Log
Instructions and Update Site Log
You can use the hyperlinks to quickly get to the section of interest or you can scroll down to read them all.
Section: 0. Form
Section: 1. Identification of the Ranging System Reference Point (SRP)
Section: 2. Site Location Information
Section: 3. General System Information
Section: 4. Telescope Information
Section: 5. Laser System Information
Section: 6. Receiver System
Section: 7. Tracking Capabilities
Section: 8. Calibration
Section: 9. Time and Frequency Standards
Section: 10. Preprocessing Information
Section: 11. Aircraft Detection
Section: 12. Meteorological Instrumentation
Section: 13. Local Ties, Eccentricities, and Collocation Information
Section: 14. Local Events Possibly Affecting Computed Position
Section: 15. On-Site, Point of Contact Agency Information
Section: 16. Responsible Agency (if different from 15.)
Section: 17. More Information
ILRS Site and System Information Form International Laser Ranging Service 0. Form Prepared by (Full Name) : Hiroo Kunimori Preparer E-mail : kuni@crl.go.jp Date Prepared : 2002-05-09 Report Type : UPDATE Site Log Format Version : 2.0 Site Log Revision : Back to top 1. Identification of the Ranging System Reference Point (SRP) Site Name : Tateyama IERS DOMES Number : 21740M001 CDP Pad ID : 7339 Subnetwork : WPLTN Description : MONUMENT Monument Description : PILLAR Monument Inscription : Tateyama_SLR-S2 Mark Description : Cross on Rotary sheet type reflective mirror Date Installed : 1998-01-01 Date Removed : Geologic Characteristic : N/A Additional Information : http://www2.crl.go.jp/t/team6/survey/2/09/ : tateyama.pdf Back to top 2. Site Location Information City or Town : Tateyama State or Province : Chiba Country : Japan Tectonic Plate : North American Local Time (UTC +/- hours) : Approximate Position X coordinate [m]: -4000964.777 Y coordinate [m]: 3375308.947 Z coordinate [m]: 3632199.533 Latitude [deg]: 35.9369 N Longitude [deg]: 139.8481 E Elevation [m]: 120.4 Survey Method : Date Measured : Additional Information : Back to top 3. General System Information 3.01 System Name : Tateyama 4-Character Code : TATL CDP System Number : 74 CDP Occupation Number : 01 Eccentricity to SRP (if Not Identical With SRP) North [m]: -4.7338 +- 0.002 East [m]: 7.3302 +- 0.002 Up [m]: 4.4586 +- 0.002 Date Measured : 1999-11-09 Date Installed : 1997-04-01 Date Removed : 2001-10-13 Additional Information : Back to top 4. Telescope Information 4.01 Receiving Telescope Type : Coude Aperture [m]: 0.75 Mount : AZ-EL Date Installed : Date Removed : Xmitting Telescope Type : Coude Aperture [m]: 0.75 Date Installed : Date Removed : Tracking Camera Type : CCD Model : ST4 Manufacturer : SBIG/EOS Field of View [deg]: 0.0167 Minimum Magnitude [mag]: 10 Date Installed : Date Removed : Transmit/Receive Path : COMMON COUDE Transmit/Receive Switch : POLARIZER Max Slew Rate Az [deg/s]: 12 Max Slew Rate El [deg/s]: 12 Max Used Tracking Rate Az : 5 Max Used Tracking Rate El : 5 Telescope Shelter : SEALED DOME Daylight Filter Type : SPECTRAL FILTER Dayl. Filt. Bandwidth [nm]: 0.3 Adjustable Attenuation : Both Adjustable Field of View : Transmit Efficiency : 0.24 Receive Efficiency : 0.06 Date Installed : 1997-04-01 Date Removed : 2001-10-13 Additional Information : Minimum Magnitude: ~10 : Transmit/Receive Switch: SHG Crystal; : substituted POLARIZER; : is that correct? rlr 07/12/2019 Back to top 5. Laser System Information 5.01 Laser Type : ND:YAG Model : Manufacturer : Number of Amplifiers : 2 Primary Wavelength [nm]: 1064 Primary Maximum Energy [mJ]: N.A. Secondary Wavelength [nm]: 532 Secondary Max. Energy [mJ]: 50 Xmit Energy Adjustable : YES Additional Information : Pulse Width (FWHM) [ps]: 35 Max. Repetition Rate [Hz]: 20 Fullw. Beam Divergence ["]: 10 Theoretical Beam Div : Measured Beam Div : Method Used : Additional Information : Final Beam Diameter [m]: 0.75 Eyesafe : NO Eyesafe Standard : JIS C6802 Polarization on Exit : Laser Fire Control : Laser Energy Monitor : Start Diode Type : Manufactorer : Model : Quantum Efficiency [%]: Rise/Fall Time [ps]: Date Installed : Date Removed : Signal Processing : Manufacturer : Model : Date Installed : Date Removed : Additional Information : Date Installed : 1997-04-01 Date Removed : 2001-10-13 Additional Information : Primary Maximum Energy: : not used for laser ranging Back to top 6. Receiver System 6.01.01 Primary Chain Wavelength [nm]: 532 Detector Type : CSPAD Manufacturer : PESO Consulting Model : KSP Quantum Efficiency [%]: 15 Nominal Gain : Rise Time [ps]: Jitter (Single PE)[ps]: 20 Field of View Diam ["]: 40 Date Installed : 1997-04-01 Date Removed : Amplifier Type : Manufacturer : Model : Gain : Bandwidth : Date Installed : Date Removed : Additional Information: Signal Processing : Time Walk Compensated Manufacturer : Graz Model : Date Installed : 1997-04-01 Date Removed : Amplitude Measurement : YES Return-Rate Controlled: NO Mode of Operation : Single to Multi Photons Additional Information: Time of Flight Observ. : EVENT Manufacturer : EOS Model : MRCS KSP Resolution [ps]: Precision [ps]: 15 Date Installed : 1997-04-01 Date Removed : Additional Information : Jitter: <20 6.02.01 Secondary Chain Wavelength [nm]: Detector Type : Manufacturer : Model : Quantum Efficiency [%]: Nominal Gain : Rise Time [ps]: Jitter (Single PE)[ps]: Field of View Diam ["]: Date Installed : Date Removed : Amplifier Type : Manufacturer : Model : Gain : Bandwidth : Date Installed : Date Removed : Additional Information: Signal Processing : Manufacturer : Model : Date Installed : Date Removed : Amplitude Measurement : Return-Rate Controlled: Mode of Operation : Additional Information: Time of Flight Observ. : Manufacturer : Model : Resolution [ps]: Precision [ps]: Date Installed : Date Removed : Additional Information : 6.03.01 Tertiary Chain Wavelength [nm]: Detector Type : Manufacturer : Model : Quantum Efficiency [%]: Nominal Gain : Rise Time [ps]: Jitter (Single PE)[ps]: Field of View Diam ["]: Date Installed : Date Removed : Amplifier Type : Manufacturer : Model : Gain : Bandwidth : Date Installed : Date Removed : Additional Information: Signal Processing : Manufacturer : Model : Date Installed : Date Removed : Amplitude Measurement : Return-Rate Controlled: Mode of Operation : Additional Information: Time of Flight Observ. : Manufacturer : Model : Resolution [ps]: Precision [ps]: Date Installed : Date Removed : Additional Information : Back to top 7. Tracking Capabilities 7.01 Satellites Very Low Alt (<400 km) : YES Low Altitude (400-2000) : YES LAGEOS/LARES : YES GLONASS : YES Etalon : YES GNSS : NIGHT Geosynchronous : Moon : NO Ave. Pass Switch Time [s]: 60 Average values for LAGEOS Single Shot RMS [mm]: 15 # of Obs per NP : 150 Use of Semi-trains : NO # of Semi-train Tracks : N.A. Range Gate Width [ns]: 200 - 10000 Beam Pointing Accuracy ["]: 5 Angle Encoder Resolution["]: 0.3 Min. Tracking Elev. [deg]: 20 Laser Polarization @emitter: Operation Months per Year : 10 Days per Week : 5 Hours per Day : 8 Staff per Shift : 0 System Shared With : R&D Time Allocated to SLR [%]: Remotely Controllable : YES Tracking Restrictions Go/No-go flag : Satellite Verification : Date Verified : Maximum elevation : Satellite Verification : Date Verified : Pass segments : Satellite Verification : Date Verified : Schedule segments : Satellite Verification : Date Verified : Maximum laser power limit: Satellite Verification : Date Verified : Date First Applicable : 1998-02-16 HH:MM UT Date Last Applicable : Additional Information : Can not br remotely controlled due : to general safety : Staff per Shift: MOSTLY NONE Back to top 8. Calibration 8.01 Calibration Type : PRE+POST Target Location : EXTERNAL Target Type : CORNER CUBE Target Structure : METAL POLE Number of Targets : Target Distance(s) [m]: 10 Date Measured : 1997-07-01 Accuracy [mm]: 1.0 Verification : 1998-07-01 Return-Rate Controlled : YES Eye-Safe Method : Additional Information : Mode of Operation : SINGLE/MULTI PHOTON Calibration performed : 5 Single Shot RMS [mm]: 8 Edit Criterion 1st Chain : ITERATIVE 2.5 SIGMA Edit Criterion 2nd Chain : N.A. Application of Cal Data : LINEAR FIT Date Installed : 1998-01-01 Date Removed : Additional Information : Back to top 9. Time and Frequency Standards 9.01.01 Frequency Standard Type : Oven Controlled Crystal Oscillator Model : XL-DC 151-602-254 Manufacturer : TrueTime Short Term Stab. [e-12]: 10 Long Term Stab. [e-12]: N.A. Time Reference : GPS Synchronization : GPS Epoch Accuracy [ns]: 100 Date Installed : 1997-04-01 Date Removed : Additional Information : 10MHz from GPS receiver 9.02.01 GNSS Timing Rcvr Model : XL-DC 151-602-254 Manufacturer : TrueTime Date Installed : 1997-04-01 Date Removed : Additional Information : 9.03.01 One-way System Calibration Date performed : Direction Calibrated : Additional Information : Back to top 10. Preprocessing Information 10.01 On-site NP Generation : YES Data Screening : IRV+POLYNOMIAL Return-Rate Rejection : Edit Criterion 1st Chain : MANUAL, ITERATIVE 2.5 SIGMA Edit Criterion 2nd Chain : N.A. Upload interval : DAILY Date First Applicable : 1998-02-16 HH:MM UT Date Last Applicable : Additional Information : Back to top 11. Aircraft Detection 11.01 Detection Type : EYESAFE LASER and MOUNT OBSERVER Manufacturer/Provider : Automatic Laser Shutoff : Alarms Recorded : Hazard Distance [km]: Date Installed : 1998-12-01 Date Removed : Additional Information : Back to top 12. Meteorological Instrumentation 12.01.01 Pressure Sensor Model : RPT301A Manufacturer : Nippon Electric Instruments Recording Interval : PER PASS Accuracy [mbar]: 0.3 Height Diff to SRP [m]: 0.1 Distance from SRP [m]: Date Installed : 1997-04-01 HH:MM UT Calibration Interval : YEARLY Date Removed : Additional Information : Three sensors to check each other 12.02.01 Temp Sensor Model : 101+N59 Manufacturer : Nippon Electric Instruments Recording Interval : PER PASS Accuracy [deg C]: 0.1 Date Installed : 1997-04-01 HH:MM UT Calibration Interval : YEARLY Date Removed : Additional Information : Two sensors to check each other 12.03.01 Humidity Sensor Model : 35D+N59CV Manufacturer : Nippon Electric Instruments Recording Interval : PER PASS Accuracy [% rel h]: 2 Date Installed : 1997-04-01 HH:MM UT Calibration Interval : YEARLY Date Removed : Additional Information : Two sensors to check each other Back to top 13. Local Ties, Eccentricities, and Collocation Information 13.01 Collocated Permanent Geodetic Systems 13.01.01.01 GNSS : CRL Date Installed : 1998-01-01 Date Removed : Additional Info : 13.01.01.02 GNSS : NO Date Installed : Date Removed : Additional Info : 13.01.02.01 DORIS : NO Date Installed : Date Removed : Additional Info : 13.01.03.01 PRARE : NO Date Installed : Date Removed : Additional Info : 13.01.04.01 VLBI : IVS Date Installed : 1994-10-01 Date Removed : Additional Info : 13.01.05.01 Gravimeter : NO Date Installed : Date Removed : Additional Info : 13.01.06.01 Other SLR : Date Installed : Date Removed : Additional Info : 13.02.01.01 Local Ties from the SRP to Other Monuments or Systems on Site Monument Name : VLBI-CP0 Instrumentation Type : VLBI Instrumentation Status : PERMANENT DOMES Number : 21740S001 CDP Number : 7338 Differential Components (ITRS) dx [m]: -28.2015 +- 0.002 dy [m]: -34.4858 +- 0.002 dz [m]: 12.3407 +- 0.002 Date Measured : 1999-11-09 Determined by : Kokusai Kogyo Co Ltd Date Installed : 1994-10-01 Date Removed : Additional Information : CRL Keystone 11 m antenna 13.02.02.01 Local Ties from the SRP to Other Monuments or Systems on Site Monument Name : SLR-PGPS Instrumentation Type : GPS Instrumentation Status : PERMANENT DOMES Number : 21740S002 CDP Number : N.A. Differential Components (ITRS) dx [m]: -14.6897 +- 0.002 dy [m]: -1.3854 +- 0.002 dz [m]: -3.9493 +- 0.002 Date Measured : 1998-12-07 Determined by : Kokusai Kogyo Co Ltd Date Installed : 1994-10-01 Date Removed : Additional Information : Ashtech Z-XII with GEODETIC L1/L2 : CDP Number: not assigned 13.03.01.01 Eccentricities Between Other Monuments on Site From: Monument Name : DOMES Number : CDP Number : To: Monument Name : DOMES Number : CDP Number : Differential Components (ITRS) dx [m]: dy [m]: dz [m]: Date Measured : Determined by : Additional Information : Back to top 14. Local Events Possibly Affecting Computed Position 14.01 Date : 2000-09-01 00:00 UT Event : See below Additional Information : The baseline length between Kashima : and Tateyama was shortened by about : 5 cm. The crustal deformation at : Tateyama, located about100 km north- : east of the Izu islands, is caused : by a dike intrusion at about 3 km : depth and co-seismic offsets between : the islands. As of mid-September : 2000, the crustal deformation around : Izu islands and the baseline : shortening had almost decayed. : Date: a few months after the end of June 2000 : Event: a dike intrusion and : co-seismic offsets between the Izu islands Back to top 15. On-Site, Point of Contact Agency Information Agency : Communications Research Lab. Mailing Address : 4-2-1, Nukui-kita, Koganei, : 184-8795 Japan Website : Primary Contact Contact Name : Hiroo Kunimori Telephone (primary) : +81 423-27-7559 Telephone (secondary) : Fax : +81 423-27-6077 E-mail : kuni@crl.go.jp Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Tertiary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : Back to top 16. Responsible Agency (if different from 15.) Agency : Mailing Address : Primary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Secondary Contact Contact Name : Telephone (primary) : Telephone (secondary) : Fax : E-mail : Additional Information : Back to top 17. More Information URL for More Information : http://ksp.crl.go.jp/ Hardcopy on File Site Map : NO Site Diagram : NO Horizon Mask : NO Monument Description : NO Site Pictures : NO Additional Information : Back to top
- NASA Official: Frank Lemoine
- Web Curator: Lori J. Tyahla
- Contact Us
- Last modified date: Nov 5, 2024
- Privacy Policy & Important Notices